Record one reading and return what it banked — the consumption, the cost, and whether it fed a meter.
Record one reading and return what it banked — the consumption, the cost, and whether it fed a meter. Offline-capable: the device and the client operation id are injected by the applier, and the pair is unique, so a replayed queue cannot bank the same reading twice. p_reading_id lets a handset name the reading so a photograph can be queued against it before it exists. On a supply point with a rollover value, a register below the previous one (or below the base reading, for the first) counts as the dial going round; that is taken as it stands only where the dial was in the top tenth of its range, and is otherwise refused as REGISTER_UNLIKELY_WRAP unless p_wrap_confirmed says somebody checked.